You are here: Company » Safety&Protection » Lightning Protection » Lightning Approaching Warning System&MEMS Electrometer

loading

Lightning Approaching Warning System&MEMS Electrometer

This lightning approaching warning system consists of an atmospheric electric field sensor, a control unit, a mounting bracket, and software. Its core functions are to measure the ground atmospheric electric field intensity, conduct real-time lightning warning, and realize data remote transmission. Adopting advanced MEMS electric field sensor technology, it has no wearable mechanical parts, and is more stable and reliable than traditional equipment, suitable for lightning risk prevention and control in various outdoor open scenarios.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button
  • MEMS

1. High-precision MEMS Sensing Technology: Equipped with a MEMS electric field sensor, the electric field measurement resolution reaches 10V/m, with accuracy better than 5%. It can accurately capture electric field changes in the range of -50kV/m ~ +50kV/m, with a response time of only 1s. It can quickly sense abnormal changes in the thundercloud electric field, provide accurate data support for lightning warning, and solve the problems of low resolution and slow response of traditional sensors.

2. Low-power and High-stability Control Unit: The control unit is centered on a high-performance ARM chip, powered by 12VDC with power consumption ≤5W, featuring both low energy consumption and high stability. It also expands multiple communication interfaces such as RS485, RS232, and 100M Ethernet, adapting to data transmission needs in different scenarios and meeting the communication diversity requirements of large-area network detection.

3. Multiple Anti-interference and Environmental Adaptability: The sensor adopts anti-static and electromagnetic interference design, combined with technology resistant to environmental temperature and humidity changes and highly reliable airtight packaging. It can work stably in complex outdoor environments, reduce the interference of temperature, humidity, electromagnetism and other factors on measurement results, ensure long-term monitoring accuracy, and lower the risk of equipment failure in harsh environments.

4. Comprehensive Alarm and Control Functions: The system is equipped with sound and light alarm functions, and also has switch output control. The relay contact capacity reaches 250VAC/5A, which can link with external equipment to realize risk disposal. It is matched with a computer display as a human-computer interaction interface to display the atmospheric electric field value and lightning warning information in real time, facilitating staff to grasp the lightning risk dynamics in time.

5. Flexible Installation and Adaptability: It is equipped with a 1.5m-high pole bracket. The bottom of the pole can be fixed with a cement foundation, and the height of the pole can also be adjusted according to different installation scenarios such as roofs and ground. The sensor supports two connection methods: wired (communication cable) and wireless, adapting to the installation needs of various outdoor open scenarios such as airports, transmission lines, and outdoor venues.


  1. Atmospheric Electric Field Sensor Electric Field Measurement Range: 50kV/m ~ +50kV/m

  2. Atmospheric Electric Field Sensor Resolution: 10V/m

  3. Atmospheric Electric Field Sensor Accuracy Better than 5%

  4. Atmospheric Electric Field Sensor Response Time 1s

  5. Atmospheric Electric Field Sensor Power Consumption: 0.65W

  6. Control Unit Power Supply Voltage: 12VDC

  7. Control Unit Power Consumption: ≤5W

  8. Control Unit Communication Interface: RS485, RS232, Ethernet (100M)

  9. Control Unit Switch Output Relay normally open/closed contact, contact capacity: 250VAC/5A

  10. Display Device Interface Mode 5-pin terminal or wireless connection

  11. Display Device Display Carrier Computer display

  12. Mounting Bracket Standard Height 1.5m (adjustable on demand)

1. Airport Runway Safety Monitoring: Installed in the open area of the airport, it monitors the change of atmospheric electric field in real time, gives early warning of lightning risk, avoids the safety hidden danger caused by lightning weather to flight take-off and landing, and ensures the airport operation order and the safety of personnel and aircraft.

2. High-voltage Transmission Line Protection: Deployed in the open area along the transmission line, it monitors the electric field around the line, sends out lightning warning in time, assists operation and maintenance personnel to take protective measures in advance, reduces line faults caused by lightning, and ensures the stable power supply of the power system.

3. Large Outdoor Venue Operation: Applied in stadiums, open-air concert venues, etc., it monitors lightning risk in real time during events. Once an early warning is triggered, it can evacuate personnel and suspend activities in time to avoid personal injury caused by lightning.

4. Forest Fire Prevention Area Early Warning: Installed at the edge of the forest or open monitoring points, it gives early warning by monitoring lightning activities, predicts the possibility of forest fires caused by lightning in advance, and gains emergency disposal time for forest fire prevention departments, reducing the probability and loss of fires.

5. Industrial Park Equipment Protection: Deployed in the outdoor area of the industrial park, it monitors the atmospheric electric field and lightning activities, gives lightning risk warning to precision equipment and high-voltage equipment in the park, avoids equipment damage by lightning, and reduces the economic loss of enterprises.


Frequent Questions
  • 1. What interference sources should the electric field sensor avoid during installation?
    Created with Sketch.
    形状 Created with Sketch.
    It should avoid buildings, antennas, chimneys, etc., and no personnel/vehicles pass within 10 meters to prevent electric field superposition interference from affecting measurement accuracy.
  • 2. What data transmission methods does the control unit support?
    Created with Sketch.
    形状 Created with Sketch.
    It supports RS485, RS232, and 100M Ethernet, and can choose wired connection or wireless connection with display device as needed.
     
  • 3. What are the requirements for installing the sensor in snowy areas?
    Created with Sketch.
    形状 Created with Sketch.
    It should be installed high enough to ensure it is not covered by snow, so as to ensure the normal monitoring function in winter.
  • 4. Does the system have other output forms besides sound and light prompts for alarms?
    Created with Sketch.
    形状 Created with Sketch.
    It has switch output with relay contact capacity of 250VAC/5A, which can link with external equipment to handle risks