Availability: | |
---|---|
Quantity: | |
SP-D-LC5
1. Best -contact detection - excludes the need to enter the personnel into hazardous areas, ensuring the safety of work.
2. General sensitivity and selectivity - reacts only to methane without the influence of other gases, which minimizes false works.
3. The efficiency in difficult conditions - a laser beam penetrates through vegetation, snow cover and other obstacles, which allows the device to use the device in the areas of permafrost and dense forests.
4. Little work and quick deployment - compatible with the UAV, allowing to examine several kilometers of pipelines in one departure, significantly increasing the effectiveness of the inspection.
1. Best -contact detection - excludes the need to enter the personnel into hazardous areas, ensuring the safety of work.
2. General sensitivity and selectivity - reacts only to methane without the influence of other gases, which minimizes false works.
3. The efficiency in difficult conditions - a laser beam penetrates through vegetation, snow cover and other obstacles, which allows the device to use the device in the areas of permafrost and dense forests.
4. Little work and quick deployment - compatible with the UAV, allowing to examine several kilometers of pipelines in one departure, significantly increasing the effectiveness of the inspection.
1. Industrial monitoring:
Examination of energy facilities (power lines, substations)
Control of oil and gas and chemical enterprises
Industrial infrastructure inspection
2. Auroral response:
Operational deployment in emergency zones
Transmission of video and telemetry in real time
3D cartography of distress zones
3. Intellectual safety:
Perimeter monitoring of urban zones
Patrolling large industrial sites
Detection of violators with IR cameras (up to 5 km)
1. Industrial monitoring:
Examination of energy facilities (power lines, substations)
Control of oil and gas and chemical enterprises
Industrial infrastructure inspection
2. Auroral response:
Operational deployment in emergency zones
Transmission of video and telemetry in real time
3D cartography of distress zones
3. Intellectual safety:
Perimeter monitoring of urban zones
Patrolling large industrial sites
Detection of violators with IR cameras (up to 5 km)
Determined gas: methane (ch)
Dimensions: 65 × 56 × 82 mm
Weight: 245 g
Measurement range: 0–99 999 ppm · m
Detection range: 0-50 m
Sensitivity: 5 ppm · m
Response time: 25 ms
Error: ± 10%
Determined gas: methane (ch)
Dimensions: 65 × 56 × 82 mm
Weight: 245 g
Measurement range: 0–99 999 ppm · m
Detection range: 0-50 m
Sensitivity: 5 ppm · m
Response time: 25 ms
Error: ± 10%